← Back to projects

Phoa House

Kuala Lumpur

Front elevation of Phoa House showing the long-span green roof and swimming pool structure

Engineering a concrete house perched on a hillslope.

Phoa House is arranged as a series of reinforced-concrete volumes that step down a hillslope in Bukit Duta. Long spans up to 18 m and cantilevers up to 5.5 m give the house its projecting form, while board-formed walls and soffits leave the structure exposed as the architectural finish.

The design sought to retain the existing slope profile, with much of the building elevated above the ground. This required a coordinated response to the concrete frame, its foundations and the stability and drainage of the hillside. The engineering extended from the behaviour of the projecting slabs to the construction measures needed to realise their geometry and finish.

Preserving the existing slope profile

The pile foundations were designed to avoid ground beams and installed using tripod rigs, preserving the original ground profile and realising the architectural vision of a building nestled lightly into the hillside.

Resolving building movement without losing the architectural form

Deflection governed the design of the long spans and cantilevers, requiring careful assessment of short-term, long-term and staged movements. Precambering and construction sequencing were integral to controlling these movements and achieving the intended architectural form.

Integrating stormwater management with the landscape

Lined swales and stone-pitched drains form part of the sustainable drainage approach, accommodating surface runoff while preserving slope stability, and seamlessly integrating stormwater management with the landscape.

Client

Architect

Design Unit Architect

Design and Build Contractor

Project Manager

Interior Designer

Years

2026

Size

Project Cost

Services

Structural engineering

Geotechnical engineering

Civil engineering

Project Status

Completed

DIVE DEEPER

The living block’s green roof spans 18 m between two slender walls and cantilevers towards the pool, with a sliding glazed façade below. Achieving the architect’s intended slim slab profile required detailed three-dimensional nonlinear finite element analysis, accounting for short-term, long-term and staged deflections. The precambering requirements and construction sequence were developed in close coordination with the contractors.

The roof geometry and its predicted deflected shape required precambering in three dimensions, adding complexity to the formwork and construction sequence. Spatial coordinates defining the precambered surface were provided to the contractor for accurate setting out and construction of the formwork.

Detailed deflection studies informed the precambering requirements and construction-stage control measures, which were discussed and agreed with the contractors.

Three-dimensional nonlinear finite element deflection study

Deflection study undertaken using 3D non-linear finite element analysis.